Home saunas

Which sauna fits your house?

Start with the room and the panel. The room's volume sets the heater size, and the heater size sets the circuit. Put in the dimensions and see both.

Heater size

6 kW heater210 cu ft. At 240 V a 6 kW heater draws 25 A.Full sizing, with log walls and running cost
A sauna bucket, ladle and birch whisk on a pale wooden bench
A traditional sauna: water from the bucket goes on the heater's stones to make steam.

Before you buy

What the panel has to carry

A heater's current at 240 V is its watts divided by 240. The breaker and wire size come from the heater's installation manual and the electrical code, and an electrician sizes them. The numbers below show why a 6 kW heater is a job for the panel, while a two-person infrared cabinet often plugs into a dedicated 120 V outlet.

Sauna electrical requirements
Heater current at 240 V
HeaterCurrentRoom volume
3 kW12.5 A2–4 m³ (70–140 cu ft)
4.5 kW18.8 A3–6 m³ (110–210 cu ft)
6 kW25.0 A5–8 m³ (180–280 cu ft)
8 kW33.3 A7–12 m³ (250–420 cu ft)
9 kW37.5 A8–14 m³ (280–490 cu ft)